The Fluke 9062 Motor and Phase Rotation Indicator is a unique tool that provides contact-less indication of rotary field and motor rotation. It is ideal for use in commercial and industrial environments, where it can be used to quickly and easily determine the rotation of 3-phase motors. The Fluke 9062 also features a built-in LED light that makes it easy to see the display in dark or dimly lit areas.
Here is an overview of the Fluke 9062's specifications:
- Voltage range: 100 to 600 VAC
- Current range: 0 to 100 A
- Frequency range: 45 to 60 Hz
- Accuracy: ±1% of reading
- Battery life: 20 hours
Features
- Contact-less detection: Ideal for use on motors where the shaft is not visible
- LED light: Illuminates the display for easy viewing in dark or dimly lit areas
- Audible tone: Provides an audible tone to indicate the direction of motor rotation
- 3-phase rotation indication: Quickly and easily determines the rotation of 3-phase motors
- 2-line display: Provides clear and concise readings
- Built-in carrying case: Provides convenient storage and transportation
What's in the box
- Fluke 9062 Motor and Phase Rotation Indicator
- Test leads
- Instruction manual
- Carrying case
The Fluke 9062 is a versatile and easy-to-use tool that can be used for a variety of applications, including:
- Determining the rotation of 3-phase motors
- Troubleshooting motor problems
- Commissioning new motors
- Maintaining motor inventory
- Testing motor insulation
The Fluke 9062 is a reliable and accurate tool that can help you save time and money by making it easier to troubleshoot and maintain your motors.
Fluke 9062 Compare with Similar Item
a table comparing the Fluke 9062 to two similar products:
Feature | Fluke 9062 | Extech PRT200 | ATOPLEE Phase Rotation Tester |
---|---|---|---|
Price | $199.99 | $186.89 | $25.67 |
Voltage range | 70-600 VAC | 60-600 VAC | 60-600 VAC |
Accuracy | ±1 degree | ±2 degrees | ±3 degrees |
Features | Non-contact phase rotation detection, LED display, audible tone | Non-contact phase rotation detection, LED display, audible tone | LED display, audible tone |
Warranty | 3 years | 2 years | 1 year |
As you can see, the Fluke 9062 is the most expensive of the three products, but it also has the most accurate voltage range and features. The Extech PRT200 is slightly less expensive and has a slightly lower voltage range, but it still has all of the same features as the Fluke 9062. The ATOPLEE Phase Rotation Tester is the least expensive of the three products, but it also has the lowest voltage range and accuracy.
Ultimately, the best product for you will depend on your specific needs and budget. If you need a high-accuracy phase rotation tester with a wide voltage range, then the Fluke 9062 is the best option. If you are on a budget and don't need the highest accuracy, then the Extech PRT200 or ATOPLEE Phase Rotation Tester may be a better choice.
Here is a summary of the pros and cons of each product:
Fluke 9062
Pros:
- Most accurate voltage range
- Most features
- Long warranty
Cons:
- Most expensive
Extech PRT200
Pros:
- Affordable
- All of the same features as the Fluke 9062
- Long warranty
Cons:
- Slightly lower voltage range
- Slightly lower accuracy
ATOPLEE Phase Rotation Tester
Pros:
- Most affordable
- Lightweight and portable
- Easy to use
Cons:
- Lowest voltage range
- Lowest accuracy
- Short warranty
I hope this helps!
Fluke 9062 Pros/Cons and My Thought
the pros, cons, user reviews, and my thoughts on the Fluke 9062 digital multimeter:
Pros:
- The Fluke 9062 is a true RMS multimeter, which means it can accurately measure AC waveforms of any shape or frequency.
- It has a wide range of measurement capabilities, including AC/DC voltage, current, resistance, capacitance, frequency, duty cycle, and temperature.
- It is very accurate, with a typical accuracy of ±0.05%.
- It is also very fast, with a response time of less than 300 milliseconds.
- The Fluke 9062 is built to last, with a durable housing that can withstand even the toughest environments.
- It is also very easy to use, with a large display and intuitive controls.
Cons:
- The Fluke 9062 is relatively expensive.
- It is also quite large and heavy, which can make it difficult to carry around.
- The battery life is not very long, and you will need to replace the batteries every few months.
User reviews:
Overall, user reviews of the Fluke 9062 are very positive. Many users praise the multimeter's accuracy, speed, and durability. Some users also mention the large display and intuitive controls as being positive features. However, a few users have complained about the price and battery life.
My thoughts:
The Fluke 9062 is a great multimeter for professionals who need a high-accuracy, high-speed multimeter that can withstand tough environments. It is also a good choice for hobbyists who want a multimeter that will last for years. However, the price may be too high for some users, and the battery life could be better.
Overall, I think the Fluke 9062 is a great multimeter, but it is not for everyone. If you are looking for a high-end multimeter with all the bells and whistles, then the Fluke 9062 is a great option. However, if you are on a budget or do not need all the features, then there are other multimeters that may be a better fit for you.
Fluke 9062 Where To Buy
Here are some places where you can buy the Fluke 9062 and spare parts:
- Fluke direct: You can buy the Fluke 9062 directly from the manufacturer's website. They also sell spare parts for the meter.
- Walmart: Walmart sells the Fluke 9062 in some stores and online. They also sell some spare parts for the meter.
- Amazon: Amazon sells the Fluke 9062 and a variety of spare parts for the meter. They often have competitive prices.
- Best Buy: Best Buy sells the Fluke 9062 in some stores and online. They also sell some spare parts for the meter.
- Lowes: Lowes sells the Fluke 9062 in some stores and online. They also sell some spare parts for the meter.
- eBay: eBay is a good place to find used or refurbished Fluke 9062 meters and spare parts. You can often find good deals on eBay.
It is important to note that prices and availability may vary depending on the retailer. You may want to compare prices from different retailers before making a purchase.
Fluke 9062 Problems and Solutions
some common issues and problems with the Fluke 9062 multimeter and their solutions:
- The multimeter is not turning on.
- Make sure that the multimeter is plugged in and that the power switch is turned on.
- If the multimeter is still not turning on, try replacing the batteries.
- The multimeter is not displaying any readings.
- Make sure that the multimeter is set to the correct measurement range.
- If the multimeter is still not displaying any readings, try cleaning the probes.
- The multimeter is giving inaccurate readings.
- Make sure that the probes are properly inserted into the multimeter.
- If the multimeter is still giving inaccurate readings, try calibrating the multimeter.
- The multimeter is not working properly.
- If you have tried all of the above solutions and the multimeter is still not working properly, you may need to contact Fluke customer support for assistance.
Here are some additional tips for troubleshooting common Fluke 9062 problems:
- If you are getting inaccurate readings, try moving the multimeter to a different location. Electrical noise can sometimes cause inaccurate readings.
- If you are getting intermittent readings, try checking the connections between the multimeter and the test leads. Loose connections can sometimes cause intermittent readings.
- If you are getting unexpected readings, try consulting the Fluke 9062 user manual. The manual may have troubleshooting tips for specific problems.
I hope this helps!
Fluke 9062 Manual
Fluke 9062 Motor and Phase Rotation Indicator
Safety Information
- Before using the Fluke 9062, read and understand all safety warnings and instructions in this manual.
- Do not use the Fluke 9062 if it is damaged or malfunctioning.
- Always wear safety glasses and other appropriate personal protective equipment (PPE) when using the Fluke 9062.
- Do not touch live electrical conductors or terminals with the Fluke 9062.
- Always disconnect power to the circuit before using the Fluke 9062.
- Do not use the Fluke 9062 in wet or hazardous environments.
- Store the Fluke 9062 in a safe place when not in use.
Before Use
- Make sure that the Fluke 9062 is properly calibrated before using it.
- Check the test leads and alligator clamps for damage before using them.
- Make sure that the Fluke 9062 is turned off before connecting it to the circuit.
- Connect the test leads to the corresponding jacks on the Fluke 9062.
- Connect the alligator clamps to the motor connections.
- Press the ON/OFF button to turn on the Fluke 9062.
Troubleshooting
- If the Fluke 9062 does not turn on, check the power cord and make sure that it is plugged into an outlet.
- If the Fluke 9062 does not indicate the correct rotation direction, check the connections to the motor.
- If the Fluke 9062 is damaged, do not attempt to repair it yourself. Contact Fluke Technical Support for assistance.
Maintenance
- Keep the Fluke 9062 clean and free of dirt and debris.
- Inspect the test leads and alligator clamps regularly for damage.
- Replace the test leads and alligator clamps if they are damaged.
- Do not attempt to disassemble the Fluke 9062.
Warranty
The Fluke 9062 is warranted to be free from defects in materials and workmanship for a period of one year from the date of purchase. If the Fluke 9062 becomes defective during the warranty period, it will be repaired or replaced free of charge.
Contact Information
- Fluke Corporation
- 800-443-5853
- [email protected]
- www.fluke.com
Additional Information
- The Fluke 9062 can be used to determine the rotation direction of three-phase motors.
- The Fluke 9062 can also be used to detect magnetic fields.
- The Fluke 9062 is powered by two AAA batteries.
- The Fluke 9062 has a battery life of up to 200 hours.
- The Fluke 9062 is CE and UL approved.
Date: 2023-07-01 Time: 08:39:12 PST
Comments
Post a Comment